Description : Xgard propose trois concepts de capteurs différents afin que vous puissiez choisir exactement ce dont vous avez besoin pour votre site.

Xgard est disponible en formats antidéflagrants, à sécurité intrinsèque ou zone sûre pour une utilisation dans tous les environnements, quelle que soit la classification.

CARACTERISTIQUES TECHNIQUES

  Type 1 Type 2 Type 3 Type 4 Type 5 Type 6
Size 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches) 195 x 166 x 111mm (7.6 x 6.5 x 4.3 inches) 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches)
Weight Nylon: 0.5 kgAlloy: 1kg (2.2lbs)316 S/S: 3.1kg (6.8lbs) Aluminium: 1kg (2.2lbs)Stainless steel: 3.1kg (6.8lbs) 1.5 kg (3.3lbs) Aluminium: 1kg (2.2lbs) Stainless steel: 3.1kg (6.8lbs)
Enclosure material ATEX certified: Glass reinforced nylon or 316 S/SUL Certified: Aluminium or 316 S/S Aluminium or 316 Stainless Steel Aluminium Aluminium or 316 Stainless Steel
Ingress protection IP65 IP54 IP65
Cable entries 1 x M20, 1/2 “NPT or 3/4 NPT* on right-side
Terminations 0.5 to 2.5mm2
Sensor type Electrochemical Catalytic bead 316 S/S sensor housing with catalytic beads Catalytic bead Thermal conductivity
Operating temperature -40 to +50 °C
(-40 to 122 °F)
(sensor dependant)
-20 to +50°C (-4 to 122°F) -40 to +80°C
(-40 to 176°F)
-20 to +150°C (-4 to 302°F) -40 to +55°C (-40 to 131°F) +10 to +55°C (50 to 301°F)
Humidity 10 to 95% RH non-condensing 0-99% RH non-condensing 0-90% RH
Repeatability Zero drift <2% FSD (Typical)<2% FSD per Month (Typical)
Response time T90 <15s OxygenT90 <30s to 120s Toxic(sensor dependant) T90 <15s (Typical)
Operating voltage 8-30V dc 2.0V dc +/- 0.1V (Typical) 10-30V dc
Power requirements 24mA maximum 300mA (Typical) 50mA at 24V dc 1.2W
Electrical output 2- wire 4-20mA (current sink) 3- wire mV bridgeTypical signal: 12-15mV/ %LEL CH4 3- wire mV bridgeTypical signal: >10mV/%LEL CH4 3- wire 4-20mA (current sink or source)
Approvals ATEX: II 1 G
Exia IIC T4 Ga
(Tamb -40 to +55°C)
UL/cUL: Class I, Div. 1
Groups A, B, C, D
IECEx
EAC
ATEX: II 2GD
Exd IIC T6 Gb (Tamb -40 to +50°C)
UL: Class I, Div. 1
Groups B, C, D
IECEx
EAC
ATEX: II 2 GD
Exd IIC T4 Gb
(Tamb -40 to +80°C)
Exd IIC T6 Gb (Tamb -40 to +50°C)
Ex tb IIIC
T180°C Db
UL: Class I, Div. 1
Groups B, C, D
IECEx
EAC
ATEX: II 2 GDExd IIC T3 Gb (Tamb -40 to +150°C) ATEX: II 2 GDExd IIC T6 Gb (Tamb -40 to +50°C)
Exd IIC T4 Gb (Tamb -40 to +80°C)
Ex tb IIIC
T180°C Db
UL: Class I, Div. 1
Groups B, C, D
IECEx
EAC
EMC compliance EN 50270       FCC Part 15    ICES- 003

*3/4 ” cable entry only available on aluminium juntion boxes.